Systems / Vacuum tower revamp and fuel gas

Unlock hidden capacity in existing assets.

Minox converts vacuum and fuel-gas deaerators to closed-loop nitrogen stripping. The tower shell stays, oxygen drops below 10 ppb, the scavenger goes to back-up, and the work is done during a turnaround.

100%

higher throughput, up to

<10 ppb

oxygen performance

0

oxygen scavenger required

0

rotating equipment added

0

rotating equipment added

Lower OPEX

and energy consumption

~7 months

fast, cost-effective retrofit

The revamp

Same tower. New way to remove oxygen

Most vacuum towers are limited by the vacuum system, not by the vessel. Take the vacuum out, and the same shell can treat more water to a lower oxygen spec.

[01]

Challenge

A vacuum tower needs two or three vacuum stages, ejectors and vacuum pumps with standby. Air leaks into the vacuum, so oxygen stalls at 50–80 ppb and a scavenger must be dosed all the time. Throughput is capped by the vacuum system.

[02]

Solution

Keep the shell and nozzles. Replace the internals with one packed bed and add the Minox closed nitrogen loop: an eductor, a heater and a catalytic deoxidiser. Nitrogen strips the oxygen, is cleaned, and goes round again.

[03]

Operation

The tower runs at slight positive pressure, so air stays out. The loop runs on pressure from the existing booster pumps. The scavenger stays connected, as back-up only.

Before and after

What stays and what you gain

Same tower, new way to remove oxygen. Before: two vacuum stages and a vacuum package. After: one packed bed and the Minox nitrogen loop.

Existing tower, nozzles and manways reused

Minimal hot work on the vessel

Below 10 ppb O₂, without chemicals

Vacuum pumps and ejectors decommissioned

Lower OPEX and power demand

Methanol or hydrogen as reactant

How the revamp works

Three steps inside the same shell

BEFORE

Conventional vacuum deaeration

Seawater trickles down through packed beds while vacuum pulls the dissolved oxygen out of the water.

  • Two vacuum stages, each a separate section of the tower
  • Vacuum package with ejector and vacuum pumps, plus standby units
  • Oxygen scavenger chemical removes what the vacuum leaves behind
  • Air leaking into the vacuum limits how low oxygen can go

Shown with two vacuum stages, the most common arrangement. Some towers use three.

Conventional two-stage vacuum tower: seawater inlet, two packed beds, stage partition, vacuum package with ejector and vacuum pumps, and oxygen scavenger injection

Summary

Vacuum tower vs. Skyfri Minox

Lead time about 7 months. Installed during turnaround. Existing tower reused.

Comparison

Vacuum tower

With Skyfri Minox

Oxygen removal

Vacuum, two or three stages

Nitrogen stripping in a closed loop

Dissolved O₂ out

Typically 50–80 ppb

Below 10 ppb

Oxygen scavenger

Continuous chemical dosing

Back-up only

Rotating equipment

Vacuum pumps and ejector, with standby

None added. The eductor runs on booster pump pressure

Tower pressure

Vacuum. Air can leak in

Slight positive pressure. Air stays out

Throughput

Limited by the vacuum system

Set by tower hydraulics, with room to grow

Maintenance

High

Low

Oxygen removal

Vacuum tower

Vacuum, two or three stages

Skyfri Minox

Nitrogen stripping in a closed loop

Dissolved O₂ out

Vacuum tower

Typically 50–80 ppb

Skyfri Minox

Below 10 ppb

Oxygen scavenger

Vacuum tower

Continuous chemical dosing

Skyfri Minox

Back-up only

Rotating equipment

Vacuum tower

Vacuum pumps and ejector, with standby

Skyfri Minox

None added. The eductor runs on booster pump pressure

Tower pressure

Vacuum tower

Vacuum. Air can leak in

Skyfri Minox

Slight positive pressure. Air stays out

Throughput

Vacuum tower

Limited by the vacuum system

Skyfri Minox

Set by tower hydraulics, with room to grow

Maintenance

Vacuum tower

High

Skyfri Minox

Low

Two conversions

Vacuum towers and fuel-gas towers

Vacuum towers

Rebuilt to run at slight positive pressure with nitrogen stripping.

More water through the same tower, oxygen below 10 ppb, and the vacuum package taken out of service.

Fuel-gas towers

Gas treatment

→

Regenerated nitrogen (≥ 99.995 %) replaces fuel gas as stripping gas.

No flaring, no corrosion inhibitor, and the hazard of stripping with fuel gas is removed.

For the engineers

What the project team asks first

[01]

What pressure does the tower run at?

Normally 1–3 barg; anything from 0 to 4 barg is doable. Minox sets the optimum for each project, balancing the upstream lift pumps against the downstream boosters.

[02]

Which utilities are needed?

Nitrogen make-up, instrument air and a small methanol feed. Motive water comes from the existing booster pumps and equalises to tower pressure after the eductor.

[03]

Is there a nitrogen purity requirement?

No. Even instrument air can be used. The catalyst removes oxygen in the make-up gas; lower purity only adds a little methanol.

[04]

What does the study cover?

Internals configuration of the existing column, reuse of distributors and support plates, the methanol supply system, and power and utility tie-ins.

References

Revamps delivered

Project and location

Operator

Capacity BWPD

Spec ppb

Year

Generation

P-18, Brazil

Petrobras

126,000

20

2005

Fuel gas conversion

Statfjord C, North Sea

Equinor

790,000

20

1998

Fuel gas conversion

A selection from the reference list.

P-18, Brazil

Operator

Petrobras

Capacity BWPD

126,000

Spec ppb

20

Year

2005

Generation

Fuel gas conversion

Statfjord C, North Sea

Operator

Equinor

Capacity BWPD

790,000

Spec ppb

20

Year

1998

Generation

Fuel gas conversion

A selection from the reference list.

Start with a study

Tell us the tower, the capacity and the next turnaround

Send the tower data sheet or P&ID. We come back with a revamp concept, an oxygen guarantee and a lead time that fits your shutdown window.